For most small UK workplaces, the law sets no fixed number of months between emergency plan reviews. It asks for something stricter: keep the plan under review and update it whenever it may no longer be valid or something significant has changed. The routine we suggest is a planned review once a year, plus an extra one the moment your premises, people or processes change, with a dated record each time.
That applies whether you run a pub, a salon, a shop, an office or a village hall. Below you will find what the rules say, which changes should trigger an early review, what to check, what to write down, and how to make it happen without relying on memory.
TL;DR
- There is no single legal interval for most small workplaces in England and Wales: the fire risk assessment, which your emergency plan rests on, must be kept under review and revised after significant changes.
- A planned yearly review is a sensible baseline. Review sooner after a fire, a near miss, building works, a layout change, new equipment, or a change in who is on site.
- Some regimes do set fixed intervals: for example, 12 months for specified residential building evacuation plans in England, and a maximum of three years for upper tier COMAH sites.
- Every review should end with a dated record: what you checked, what changed, who owns the plan and who was told.
- A digital logbook with reminders stops the review date from slipping.
Table of Contents
- What the law says about review frequency
- When a fixed interval does apply
- Why a yearly review is the sensible routine
- Changes that should trigger an early review
- What to check in a review
- What to record when you finish
- Why reviews slip, and how to stop it
- Our view
- Put the review date in a logbook
- FAQ
- Sources
What the law says about review frequency
In England and Wales, the emergency plan for a normal workplace sits under the fire risk assessment required by the Regulatory Reform (Fire Safety) Order 2005. The person responsible for the premises (the “responsible person”) must review the assessment regularly so that it stays up to date, particularly if it may no longer be valid or there has been a significant change. The same article requires the assessment or review, with its findings, to be recorded in the cases it covers.
Notice what is missing: a number. The Order says “regularly” and “significant change”, not “every 12 months”. That is why so many guides say “annually” without pointing to a statute. Annual is a good habit, not a statutory deadline for an ordinary shop or office.
GOV.UK’s guide to fire safety risk assessment for offices and shops says the assessment should be kept under constant review and revised if there is reason to suspect it is no longer valid or a significant change has affected fire precautions. It also notes that in small offices and shops the emergency plan may be no more than a fire action notice. So your plan may be one page. The review still needs doing, and it still needs a date.
If you are not sure who counts as the responsible person at your site, our guide to who the responsible person for fire safety is sets it out in plain terms.
Scotland and Northern Ireland have their own fire safety legislation, so if you operate there, check the equivalent requirements with your local fire and rescue service.

Do you have to write the plan down?
London Fire Brigade says the emergency plan must be recorded if an Alterations Notice requires it, if you employ five or more people, or if the premises are licensed, such as a pub, club, theatre or cinema. It also advises testing the plan by practising it regularly. If you employ fewer than five people and the site is unlicensed, writing the plan down is still good practice, and it is the only way to prove later that you reviewed it.
GOV.UK’s fire risk assessment checklist is direct about the review itself: you must keep a record that you have reviewed the fire risk assessment and the date you did so.
HSE adds the wider health and safety angle. Its emergency procedures page explains that the Management of Health and Safety at Work Regulations 1999 cover emergencies, and that people respond reliably when they are well trained, take part in regular and realistic practice, and have clearly agreed, recorded and rehearsed plans.
When a fixed interval does apply
Two regimes do put a number on it. You are unlikely to fall under either as a small site, but it explains why you see different answers online.
| Regime | Who it covers | Review interval |
|---|---|---|
| Fire Safety Order 2005, article 9 | Most non-domestic premises in England and Wales | “Regularly”, and after significant change; no fixed number |
| Fire Safety (Residential Evacuation Plans) (England) Regulations 2025 | Responsible persons for specified residential buildings in England | Within 12 months of first preparing the plan, then every 12 months, and whenever there is reason to think it needs amending |
| COMAH Regulations 2015, regulation 12 | Operators of upper tier major hazard establishments | Review and test at suitable intervals not exceeding three years |
If your village hall, pub or salon is an ordinary non-domestic premises, the first row is yours. A shop with a flat above it, or a hall that shares a building with housing, should check whether the building falls into a different category.
Why a yearly review is the sensible routine
Because the law says “regularly”, you need your own interval, and one that you can defend if an inspector asks. A yearly cycle works for most small sites for three reasons.
- It is easy to remember and easy to prove. “Reviewed each November, signed and dated” is a clear answer. “Reviewed when we thought of it” is not.
- It catches slow drift. Staff leave, a storeroom fills up, a fire exit gets propped, a new member of the team never saw the assembly point. None of these feels like a “significant change”, but together they make the written plan wrong.
- It fits with other yearly jobs. Many sites already do annual fire training or a yearly risk assessment refresh. Reviewing the plan just before training means the training can pass on any changes.
Higher-risk premises (sleeping accommodation, lots of public in the building, flammable materials, late-night licensed trade) should review more often than that. A busy pub with a mixed bar and kitchen staff, with regular staff turnover, may want a six-monthly check of the plan itself, even if the full risk assessment is yearly. That is our judgement, not a legal rule, and the more risk and turnover you have, the shorter the gap should be.
Changes that should trigger an early review
The date on the calendar is only half the answer. GOV.UK’s guide lists the kinds of change that mean the assessment, and so the plan, should be looked at again:
- changes to work processes or new equipment
- building alterations or changes to the internal layout
- substantial changes to furniture
- bringing in, or storing more of, hazardous substances
- failure of a fire precaution
- significant changes in stock levels
- a significant increase in the number of people present
- people with disabilities who need to be able to leave safely
It also says that if a fire or a near miss happens, this could indicate the existing assessment is inadequate, and you should carry out a re-assessment and identify the cause before revising the plan.
Translated into daily life at a small site:
- A pub puts a marquee or heated smoking shelter in the garden, adds a function room, or changes the licensed capacity.
- A salon brings in new chemical stock, adds a treatment room or moves the chairs and the back-room store.
- An office takes on a new tenant, rearranges desks across an escape route, or moves to hybrid working so the headcount and the fire wardens change.
- A village hall starts hosting evening classes, a nursery group or a regular event with many more people, or a trustee who held the plan steps down.
A failed fire drill belongs on that list too. If people took too long to leave, the roll call went wrong or a route was blocked, the plan did not work, and waiting for next year’s review wastes the lesson. A simple fire drill log turns that into a recorded finding you can act on.
Work that has its own rules
Some tasks carry emergency arrangements of their own, such as rescue planning for anyone working above ground level. If your contractors or staff do that kind of work, the working at height regulations guide explains how those rules apply, and that plan needs its own review alongside the building evacuation plan.
What to check in a review
A review is not a rewrite. It is a structured read-through of the plan against reality. Walk the premises with the plan in your hand and ask:
- Is the plan still accurate for the building? Escape routes clear, doors opening as intended, assembly point still safe and reachable, signs still in the right place. Our fire signage guide helps with the last point.
- Are the people right? Named responsible person, fire wardens or marshals, first aiders, and contact numbers all current. Does everyone on today’s rota know what to do?
- Has anything changed since the last review? Use the trigger list above, including changes in how people use the building.
- Did the last fire risk assessment flag anything? If it asked for actions, are they closed?
- What did the drills show? Any corrective actions from drills or alarm tests should be completed and written up. If you need a reminder of the cadence for alarms, see fire alarm test frequency.
- Do the supporting checks still match? Emergency lighting, fire doors, extinguishers and first aid kit are all part of an emergency plan working in practice. Our guides on fire door check frequency and the emergency lighting monthly test cover those.
- Is anyone at particular risk? Disabled staff, visitors or regular hall users may need a personal emergency evacuation plan.
What to record when you finish
A review that is not written down cannot be proved. Whatever format you use, end each review with:
- the date of the review and who carried it out
- the version of the plan now in force, and the version it replaced
- what you checked and what you found
- what changed in the plan, and why
- any actions raised, with an owner and a due date
- who was told about the changes, and when (staff briefing, notice board, volunteers)
Then put the updated plan where people will actually find it, and take the old one out of circulation. Old copies pinned in a back office are a common way for staff to follow outdated instructions. Our guide on safety document version control shows a practical way to keep one current version, and the safety audit trail guide covers how to evidence what you did.
A worked example
Imagine a pub with 12 staff that reviews its emergency plan every November. In March it converts a storeroom into a small function room. The plan says nothing about it, and the escape route from that room now passes through the kitchen. That is a layout change and a capacity change, so the manager reviews the plan in March, not November. They update the route, add a notice, brief the team, run a drill and log it. In November the yearly review then has a clean trail: a March entry, a drill record and a signed version. If an inspector asked, the manager could show not just that a plan exists, but that it is kept alive.

Why reviews slip, and how to stop it
Reviews rarely fail for lack of intent. They fail because the date lives in one person’s head, the plan sits in a drawer, the last review has no record, and the person who did it has since left. The fix is dull but effective: put the review in a recurring schedule, name an owner and a deputy, and keep the evidence next to the other checks.
If you want a way to schedule the review, see our guide to creating a compliance calendar, and for what to keep in your files, the health and safety file contents guide. If you are weighing up the format, paper against digital logbooks compares the two for small sites.
Our view
Most small-site owners tell us, in one way or another, that they know the plan needs reviewing and that the date went past. The law asks for regular review, not a magic number, so what an inspector, an insurer or your own conscience will look for is a routine you can show.
We built Gribit around that idea. A review is just another recurring check: it has a due date, an owner, a result and a follow-up. When it sits in the same place as your fire alarm tests and first-aid kit inspections, with reminders and the supporting certificates stored alongside, it stops being the job that gets forgotten.
Paper logbooks and spreadsheets can hold the information, but they rely on someone remembering to open them. Automated reminders and centralised records also make handover easier when a manager or volunteer moves on, which is exactly when plans go stale.
Jon
Put the review date in a logbook
Gribit is a digital logbook for small businesses. You schedule recurring safety checks, record results, manage follow-up actions, store certificates and documents, assign staff access, automate reminders and export your records, organised by site, item or location. Add your emergency plan review as a recurring check, attach the current plan and the drill record, and the reminder arrives when the review is due.

The Site Logbook Annual Plan costs £49 per year per site. You can see how it works on the Gribit site, or read what a digital logbook costs for a small UK business in our 2026 cost guide.
FAQ
How often should an emergency plan be reviewed at a minimum?
For most workplaces in England and Wales there is no fixed minimum in the law. The fire risk assessment must be kept under review and revised after significant change or if it may no longer be valid. A yearly review is a sound baseline, with extra reviews after changes, incidents or failed drills.
Is a yearly review a legal requirement?
Not for an ordinary non-domestic premises: the Fire Safety Order requires regular review, not a set date. Fixed intervals do exist elsewhere, such as every 12 months for specified residential building evacuation plans in England. Choose a yearly cycle so you can show you reviewed regularly.
Do I need to write down the review?
GOV.UK’s checklist says you must keep a record that you reviewed the fire risk assessment and the date. London Fire Brigade says the emergency plan must be recorded if you employ five or more people or the premises are licensed. Either way, a dated record is your evidence.
What should trigger an early review?
Building works, layout changes, new equipment or substances, a rise in the number of people present, a fire or near miss, a failed precaution, or a new person who needs help to evacuate. A drill that exposes a problem should prompt one too.
Who should do the review?
The responsible person is accountable, and may delegate the walk-round to a manager, warden or trustee. If you are unsure who holds that role at your site, check the responsible person guide and name an owner and a deputy in the plan.
Sources
- The Regulatory Reform (Fire Safety) Order 2005, article 9
- GOV.UK: Fire safety risk assessment, offices and shops
- GOV.UK: Fire risk assessment checklist (2024)
- London Fire Brigade: Your emergency plan
- HSE: Emergency procedures
- The Fire Safety (Residential Evacuation Plans) (England) Regulations 2025
- The Control of Major Accident Hazards Regulations 2015, regulation 12
- Regulations for working at heights guide